Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Laminar Flow Cabinet
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Balance
- Medical Destroyer
- Blood Bag Tube Sealer
- Furnace
- Hospital Furniture
- First-Aid Products
- Ophthalmic Equipment
- ENT Equipment
- Home Care Equipment
Infant warmer BT-550 is intended to emit controlled, evenly distributed overhead heat to the body of premature infant and other new-borns who cannot effectively regulate their body temperature. This device can be used before any treatment or operation of infant.
The BT-550 is intended to emit controlled, evenly distributed overhead heat to the body of premature infant and other newborns that cannot effectively regulate their body temperature. This device can be used before any treatment or operation of infant. The device has two operating functions; one is baby mode, and the other one is manual mode. In the baby mode, the temperature is controlled by skin temperature of infant. The skin temperature of infant compared to the temperature setting. The set value is lower than the measured value the heater of device is operate to increase the value. In the manual mode, the device is operates for predefined time.
The device has the option for weighing scale and SpO2 measuring functions. Weight and SpO2 of infant can be measured using the options. In the SpO2 measurement, the sensor is place at the end of a finger. By measuring the intensity of reflected light, depending on the concentration of dissolved oxygen in the blood determines the oxygen concentration.
Specification
Functional Characteristics |
|||||||
Temperature |
Infrared Heater |
||||||
Operation Mode (Each of tolerance range is ± 20%) |
-Prewarm (100% @28㎽/㎠) -Baby mode (100% @ 28 ㎽/㎠) -Manual (100% @ 8 ㎽/㎠) |
Manual Control Range |
0 ~ 100%, 20levels |
||||
Skin Display Range |
26 ~ 42°C ±0.3°C |
Output Power |
600W |
||||
Skin Control Range |
34 ~ 38°C (in Baby Mode) |
|
|
||||
Display |
APGAR |
||||||
Type |
7" TFT Color LCD |
Setting Range |
0sec ~ 59min 59sec |
||||
Alarm |
6 Events Alarms |
Indicating Beep |
1, 5, 10min |
||||
Examination Lamp |
Function |
||||||
LED |
40W(10W x 4ea) |
Microprocessor Controlled |
|||||
Brightness |
3levels |
Rotation of Head |
90° (Left, Light both Directions) |
||||
Illumination |
> 7,000lx |
Tripod Water Level |
|
||||
Power |
PC Interface |
||||||
Input |
AC 100/240, 50/60Hz |
RS232C |
|
||||
Consumption |
750VA |
|
|
||||
Standard Configuration (Fixed height stand) |
|||||||
Skin Temperature Sensor |
2ea |
Mattress Quick guide |
1ea 1ea |
||||
Power Cord |
1ea |
Operation manual |
1ea |
||||
Options |
Weight limit or Angle |
Options |
Weight limit or Angle |
||||
Lifting Stand |
|
IV Pole |
Approx. 5 kg |
||||
IV Plate |
Approx. 11 kg |
Weighing Scale |
0 ~ 10.0 kg, ±50g |
||||
Basket(Drawer) |
Approx. 10 kg |
Masimo SpO2 |
|||||
Basket Partition |
Extension for SpO2 |
||||||
Tilting Bed |
±15° |
||||||
Physical Characteristics |
|||||||
Dimension |
Weight |
||||||
Standard |
1,027(W)x690(D)x1,890(H)mm |
Standard |
83 Kg |
||||
Fixed stand Lifting stand |
725(H) mm 615 ~ 815(H)mm |
Full option |
98 kg |
||||
Mattress |
495(W) x 810(D) x 27(H)mm |
with Safe Working Load |
Approx. 124kg |
||||
Packing |
1,150(W)X750(D)x1,550(H)mm |
Packing |
126Kg(Full Option) |
||||
Operation environment |
Storage environment |
||||||
Temperature |
18 ~ 30°C (64.4 ~ 86°F) |
Temperature |
–10 ~ 60°C (14 ~ 140°F) |
||||
Humidity |
0 ~ 95% non-condensing |
Humidity |
0 ~ 95% non-condensing |
||||
Air pressure |
70~106 kPa |
Air pressure |
70~106 kPa |
||||
Standard |
|
||||||
IEC60601-1, IEC60601-1-2 IEC60601-2-21, ISO 80601-2-61 |
|
||||||
Masimo Oximeter |
||
Range |
Saturation (% SpO2) Pulse Rate (bpm) Perfusion |
1% - 100% 25 - 240 0.02% - 20% |
Accuracy |
Saturation (% SpO2) – During no motion conditions Neonate |
70% - 100%, ± 3 digits 0% - 69%, unspecified |
Saturation (% SpO2) – During motion conditions Neonate |
70% - 100%, ± 3 digits 0% - 69%, unspecified |
|
Pulse Rate (bpm) – During no motion conditions |
25 to 240, ± 3 digits |
|
Pulse Rate (bpm) – During motion conditions |
25 to 240, ± 5 digits |
|
Resolution |
Saturation (% SpO2) Pulse Rate (bpm) |
1% 1 |
Low Perfusion Performance |
> 0.02% Pulse Amplitude and % Transmission > 5% |
Saturation (%SpO2) ± 2 digits Pulse Rate ± 3 digits |
Interfering Substances |
Carboxyhemoglobin may erroneously increase readings. The level of increase in approximately equal to the amount of carboxyhemoglobin present. Dyes or any substances containing dyes that change usual arterial pigmentation may cause erroneous readings. |
|
Power |
Voltage Input Range Max. AC power consumption Rechargeable battery |
90 – 240 VAC, 47 – 63 Hz 20 VA Up to 7 hours battery life |
Fuses |
0.75A, Time Delay, 250 V |
|
Isolation |
Chassis Leakage current Ground resistance |
Less than 100 ㎂mp Less than 1.0 Ω |
Environment |
Operating temperature Storage temperature Relative humidity Operating altitude |
41℉ to +104℉(5℃ to + 40℃) -40℉ to +158℉(-40℃ to + 70℃) 5% to 95% non-condensing 500 mbar to 1060 mbar pressure -1,000ft to 18,000ft(-304m to 5,486m) |
Circuitry |
Microprocessor controlled Automatic self-test of oximeter when power on Automatic setting of default parameters Automatic alarm messages Trend data output of SpO2, pulse rate |
|
Auto indicators |
Adjustable volume audible pulse: OFF and 33% to 100% in 4 steps Adjustable volume audible alarm tone: levels and 33% to 300% in 4 steps Alarm silence (120 seconds); all mute (continuous silence) Smart tone ON/OFF: excessive motion and low perfusion conditions pulse tones Pulse rate out-of-limits alarm SpO2 level out-of-limits alarm Sensor conditions alarms System failure and battery low alarms |
|
Physical characteristics |
Dimensions
Weight |
8.2” x 6.0” x 3.0” (20.8cm x 15.2cm x 7.6cm) 2.1 lbs, 32 oz (0.928 kg) |
Modes |
Averaging mode Sensitivity |
2,4,8,10,12,14 and 16 seconds Normal, APOD, and MAX |