Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Laminar Flow Cabinet
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Balance
- Medical Destroyer
- Blood Bag Tube Sealer
- Furnace
- Hospital Furniture
- First-Aid Products
- Ophthalmic Equipment
- ENT Equipment
- Home Care Equipment
Features
Parameter versatility from recovery to post-op
- BM7 offers wide application coverage from recovery ward up to ICU, pre-op, post-op, & quick surgery application with Bionet’s engineering BMGA Multi-gas analyzer as well as main and side stream EtCO2 capnography.
User friendly display design & Interface
- 12.1″ LCD touch screen that displays clear and enlarged parameters, allowing care-givers to get access to operational measurement in tip of their fingers.
Pop up menu
- All Bionet patient monitors offer Pop-up trend for ECG events with ST segment analysis for easy recognition.
INOP alarm
- Adds operational values with informing users to acknowledge immediate physiological & technical alarms of IEC60601-1-8 requirement.
Excellent network connectivity
- Features care-givers’ workflow demand from patient admission to discharge with barcode readers and ID by direct HL7 interface. Its central connectivity allows up to 64 monitors (16 wireless monitors) that permits users to manage patient data with remote NIBP triggering, alarm settings, and exporting to HER
Parameters | Product Specifications | Value |
---|---|---|
Hardware specification | Dimension (H x W x D) | 245 x 322 x 225 mm |
Weight | Approx. 4.5kg | |
Power | AC 100-240V (50/60Hz), Adapter 18 V, 2.8 A | |
Display | 12.1"color TFT LCD | |
Resolution | 1024 x 768 pixels | |
Parameters | ECG, Heart Rate, Respiration Rate, SpO2, Pulse Rate, Systolic BP, Diastolic BP, Mean BP, 2 x Temperature, 2 x IBP, EtCO2, FiCO2, Airway Respiration Rate, Anesthetic Gas Concentration in inhalation and exhalation | |
Traces | 6 waveforms : 2*ECG, SpO2, RR or EtCO2 or MGAS, 2*IBP Sweep speed : 6.25, 12.5, 25, 50 mm/sec |
|
Indicators | Categorized alarms (3 priority levels) Visual alarm lamp handle QRS beep & SpO2 pulse beep Percent(%) SpO2 pitch tone External power LED, Battery status Touch screen, rotary knob |
|
Interfaces | DC input connector: 18VDC, 2.8A LAN digital output for transferring data Nurse call system connection: • 0.3A at 125VAC • 1A at 24VDC DC output: 5VDC, 1A (Max) External monitor connection: HDMI USB barcode reader USB data storage |
|
Battery | Rechargeable Li-ion battery 2 hours for continuous operation (Option: using additional battery, total of 4 hours) |
|
Thermal Printer (optional) | Speed : 25, 50mm/sec Paper width : 58mm |
|
Data Storage | 168 hours trends data, 20 cases of 10 sec alarm waveform | |
Language | English, French, Spanish, Italian, Germany, Chinese, Russian, Czech, Bulgarian, Portuguese, Romanian, Hungarian, Turkish, Polish, Korean | |
Environment | Temperature | Operation: 5 ~ +40 °C (41 ~ 104 °F) Storage: –20 ~ +60 °C (–4 ~ +140 °F) |
Humidity | Operation: 30% ~ 85%, Storage: 10% ~ 95% (Package ) |
|
Altitude | Operation: 525 ~ 795 mmHg (70 ~ 106 kPa) Storage: 375 ~ 795 mmHg (50 ~ 106 kPa) |
|
ECG | Lead type | 3-lead, 5-lead |
Lead Selection | 3-lead : I, II, III 5-lead : I, II, III, aVR, aVL, aVF, V |
|
ECG waveforms | 3-lead : 1 channel 5-lead : 2/7 channels |
|
Heart Rate Range | Adult : 30 – 300 bpm Neonate/Pediatric : 30 – 350 bpm |
|
Heart Rate Accuracy | ±1bpm or ±1%, whichever is greater | |
Sweep speed | 6.25, 12.5, 25, 50 mm/sec | |
Filter | Diagnosis: 0.05Hz ~ 150Hz Monitoring: 0.5 ~ 40 Hz Moderate: 0.5 ~ 25 Hz Maximum: 5 ~ 25 Hz |
|
S-T segment detection range | -2.0 to 2.0 mV | |
Arrhythmia analysis | ASYSTOLE,VTACH,VFIB,BIGEMINY,ACCVENT, COUPLET,IRREGULAR, PAUSE,PVC,RONT,TRIGEMINY,VBRADY, SHORTRUN | |
Pacemaker Detection Mode | Indicator on waveform display (user selectable) | |
Protection | Against electrosurgical interference and defibrillation | |
Respiration Performance | Method | Thoracic impedance |
Channel selection | RA-LA or RA-LL | |
Measurement range | 5 – 120 breaths per minute | |
Accuracy | ±1 breath per minute | |
Apnea alarm | Yes | |
SpO2 Performance | Saturation range | 0 to 100% |
Saturation accuracy | 70 to 100% ±2 digits 0 to 69% unspecified |
|
Pulse rate range | 30 to 254 bpm | |
Pulse rate accuracy | ±2 bpm | |
NIBP Performance | Method | Oscillometric |
Operation Mode | Manual/Automatic/Continuous | |
NIBP Performance | Measurement range | Systolic : 40 to 260 mmHg MAP : 26 to 220 mmHg Diastolic : 20 to 200 mmHg |
Accuracy | mean error: less than ±5 mmHg standard deviation : less than 8 mmHg Meets accuracy requirements of ANSI/AAMI SP10:1992 and 2002 (*SunTech) |
|
Temperature Performance | Measurement range | 0 to 50℃ (32 to 122℉) |
Accuracy | 25 to 50℃: ±0.1℃ 0 to 24℃: ±0.2℃ |
|
Compatibility | YSI Series 400 temperature probes | |
IBP Performance (Optional) | Channels | 2 |
Measurement range | -50 to 300mmHg | |
Accuracy | Less than 100mmHg : ±1mmHg Equal or greater than 100mmHg : ±1% of reading |
|
Pulse rate measurement range | 0 to 300 BPM | |
Zero balancing | Range : ±200mmHg Accuracy : ±1mmHg Drift : ±1mmHg over 24 hours |
|
Transducer sensitivity | 5µV/V/mmHg | |
Sidestream CO2 (Optional) | Measurement range | 0 to 150 mmHg, 0 to 19% |
Accuracy | 0-40mmHg ±2 mmHg, 41-70mmHg ±5% of reading 71-100mmHg ±8% of reading, 101-150mmHg ±10% of reading |
|
Respiration rate | 2 to 150 breaths per minute | |
Respiration accuracy | ±1 breath per minute | |
Measurement range | 0 to 150 mmHg, 0 to 19% | |
Accuracy | 0-40mmHg ±2 mmHg, 41-70mmHg ±5% of reading 71-100mmHg ±8% of reading, 101-150mmHg ±10% of reading |
|
Respiration rate | 0 to 150 breaths per minute | |
Respiration accuracy | ±1 breath per minute | |
Anesthetic GAS/O2 - Phasein (Optional) | Method | Infra-red absorption characteristic |
Gas | CO2, O2, N2O, Des, Iso, Enf, Hal, Sev | |
Warm-up time | Main stream (IRMA AX+): • Iso accuracy mode: 45s • Full accuracy mode : 60s Side stream (ISA OR+/ AX+) : <20s |
|
Sample flow rate (for ISA OR+/AX+) | 50 ± 10 ml/min | |
Measuring Range | CO2 : 0 ~ 15 % N2O: 0 ~ 100% Hal/Iso/Enf: 0 ~ 8% Sev: 0~10% Des: 0 ~ 22% O2: 0 ~ 100%(ISA OR+/AX+) |
|
Respiratory Rate | 0 ~ 150bpm ± 1bpm |