Your position:Home> Products>>

Products

FETAL XP

Fetal Monitor

Make:Bionet Korea

Features

Rotatable, touch screen with intuitive functional keys to streamline workflow
  • 7” LCD rotatable, touch screen with 10 smart keys to streamline workflow of NST/CTG with fast, accessible trend mode
Graphic and Text mode
  • With easy recognition numeric data as well as wave display mode, care-givers can easily understand babies’ heart rates as well as UC movements.
Clinical & customizable note entry
  • Features 15 clinical notes & customizable 85 notes with password-able function for any further clinical reference of patient data
FC Central (Fetal central monitoring connectivity)
  • All Bionet fetal monitors have connectivity with FC Central monitoring system for data management for HIS as well as multiple remote viewer mode.
Integrated CTG/NST analysis
  • All Bionet fetal monitors have integrated CTG and NST as it features with detailed final report review and print-out.
Convenient CTG file conversion to JPG
  • User can convert CTG data into JPG to transfer to external USB memory
Auto mode for data accuracy
  • Auto TOCO zeroing & Auto fetal movement modes ensure data accuracy
Enhanced patient data storage up to 480 hrs
  • 480hr of trend capacity is easily traceable with touch of a screen so that users can easily understand FHR and UC changes in no time.
Product Specifications Value
Printing Speed
1,2,3cm/min,( Real time)
30 cm/min (Trace, 2,3 cm/min setting)
20 cm/min (Trace, 1 cm/min setting)
Fetal Heart Rate
Input Signal : Ultrasound pulsed doppler
FHR detection method : Autocorrelation
FHR range : 50~210
FHR accuracy : 120~160bpm : ±1 bpm
Except 120~160 : ±2 bpm
Ultrasound Tranducer
Operating mode : PWD Mode
Transducer Type : 9-crystal
Ultrasound frequency : 1.0MHz
Pulse Repetition Frequency : 3125Hz
Spatial-Peak Temporal Average Intensity : <10mW/cm2
Display 7” Wide (800 X 480)
User Interface Short Key
Printer Resolution
Method : Thermal Array Print
Type: Z-folder
"Print speed : 1,2,3cm/min,( Real time)
30 cm/min (Trace, 2,3 cm/min setting)
20 cm/min (Trace, 1 cm/min setting)"
Paper feeding function
Auto CTG Analysis
Average Baseline FHR
Number of TOCO
Number of Acceleration
Number of Deceleration : Late, Early, Variable
High/Low Episode
Short term Variability
Signal Loss
* CTG Analysis results is printed out every 10 minutes
Uterine Contraction
Input Source : External Transducer
Reference Control : One touch switch / Auto zeroing
Measurement range : 0~99
Line Power Input : 100~240VAC, 50~60Hz, 1.5A, Single phase
Battery type Lithium ion
Battery Capacity
Li-ion : 3 hours ( charging)
5 hours(discharging)
Data Storage Storage for 480 hours
Environmental Operation
• Operating Temperature: 10°C to 40°C (50°F to 104°F)
• Storage Temperature: - 10°C to 60°C (14°F to 140°F)
• Operating Humidity: 30% to 85% RH
• Storage Humidity: 20% to 95% RH
• Operating Attitude: 70(700) to 106Kpa(1060mbar)
• Storage Attitude: 50(500) to 106Kpa(1060mbar)
Dimensions 303(w)x.300(H)x244(D)(Approx. 4.7Kg)
Default Alarm Settings
Alarm Parameter: ON
Alarm Limit: 160, 120
Alarm Level: Medium

Copyright © 2001-2020 MKJ Associates. All Rights Reserved.