Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Laminar Flow Cabinet
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Balance
- Medical Destroyer
- Blood Bag Tube Sealer
- Furnace
- Hospital Furniture
- First-Aid Products
- Ophthalmic Equipment
- ENT Equipment
- Home Care Equipment
Features
Intuitive shortcut keys
- FC700 has simplifying keys for prompt access functions as well as streamlining workflow to reduce patient and care-giver’s stress.
Distinctive 7 segment LED
- Easy to recognize with bright 7 segment LED for patient data and operational advice without data confusion for FHR and UC
All-in-one but affordable
- With the single fetus features, CTG and NST are integrated as standard coming with detailed final report & print-out.
FC Central (Fetal central monitoring connectivity)
- All Bionet fetal monitors have integrated CTG and NST as it features with detailed final report review and print-out.
Product Specifications | Value |
---|---|
Printing Speed | 1, 2, 3 cm/min |
Fetal Movement Measurement |
Detection Source : Ultrasound pulsed doppler
Recording Method: ① Spike-like waveform on UC channel denotes relative intensity and duration of Fetal Movement. ② Dot marks between FHR and UC channels when FM intensity exceeds selected threshold. |
FHR Measurement |
Input signal : Ultrasound pulsed doppler
Ultrasound Frequency : 1.0 MHz Ultrasound Power : 0.87mW/cm2 FHR Detection Method: Auto correlation Measurement Range : 50 ~ 240 beats per minutes(BPM) FHR Accuracy : ±1 bpm over normal FHR range Ultrasound Sensitivity : 95dB at 150mm |
UC Measurement |
Input Source : External Transducer with strain gauge
Frequency Response : DC ~ 0.5 Hz Reference(Zero) Control : One touch switch Measurement Range : 0 ~ 99 units |
Display | 7-Segment LED 2 Channels (FHR, UC) |
Function | Even Mark Function |
Printer Resolution |
Recorder Method : Thermal Array Type
Resolution: 8(vertical)/10(horizental) dot/mm Print Speed : 1, 2, 3 cm/min Paper Feeding Function Paper Grid : On/Off Print Contrast : 1, 2 Auto Print Period : 0, 10, 20, 30, 40, 50, 60 Fetal movement: On/Off |
Electrical |
Input signal : Ultrasound pulsed doppler
Ultrasound Frequency : 1.0 MHz Ultrasound Power : 0.87mW/cm2 FHR Detection Method: Auto correlation Measurement Range : 50 ~ 240 beats per minutes(BPM) FHR Accuracy : ±1 bpm over normal FHR range Ultrasound Sensitivity : 95dB at 150mm |
Line Power |
Power Adaptor ;BPM050S18F02
BridgePower Corp. Input 100~240V, 50~60Hz, 1.5A Output 18V, 2.8A |
Environmental Operation |
Operating Temperature:10°C to 40°C (50°F to 104°F)
Storage Temperature:- 20°C to 60°C (-4°F to 140°F) Operating Humidity:30% to 85% RH, non-condensing Storage Humidity:10% to 95% RH, non-condensing Operating Altitude:70(700) to 106Kpa(1060mbar) Storage Altitude:50(500) to 106Kpa(1060mbar) |
Environmental Storge/Ship |
Ambient Temperature: -10 to 60℃
Relative Humidity: 20 to 95% Atmospheric Pressure: 50 to 106KPa |
Indicator |
Heart Rhythm (Green : Stable, Red : Unstable)
Alarm On/Off State Print On/Off State AC Power (Green LED) |
Sound |
Doppler Sound with Volume Control (8 steps)
Alarms Sound Information Sound : Dop Probe off, Paper off, Set-up Data Storage NST End |
Set-up |
Alarm Upper/Lower Limit Value
Alarm check delay time Print Speed Paper Grid Print Contrast Auto Print Period(NST time) Time / Date Fetal Movement OFF/FM+FMD/ FMD Only Fetal Movement Detection Threshold Demo ON/OFF BED Number CTG ON/OFF |